Distribution

Project consisted of the underground conversion of 3.0 miles of primary & secondary electrical distribution system plus voltage conversion to 12.5kV.

Several distribution conversion to underground projects were completed to replace aged overhead distribution lines, increase circuit capacity and reliability, and to increase the circuit voltage 12.5kV. 

Project consisted of the conversion to underground of the primary & secondary electrical distribution lines in “JC Penney Alley”. 

Project consisted of the conversion to underground of 2.7 miles of primary & secondary electrical distribution lines.

Projects consisted of the complete reconstruction of various sections of single-phase and three-phase overhead distribution line throughout the City of Charlevoix's electrical distribution system.

A ten-year electrical system masterplan was completed for the City of Harbor Springs to prioritize capital improvement projects and improve system capacity and reliability.

Project consisted of the initial phase of primary & secondary electrical distribution conversion to underground within the cental business district of this resort community.

Project consisted of the reconstruction of 20 miles of three-phase overhead distribution line. A total of five RUS distribution work plan rebuilds were included in this project.

Project consisted of the replacement of 200A dead-front sectionalizing cabinets with 600A S&C PMH switchgear.

Project consisted of the relocation of 0.5 miles of double circuit, three-phase overhead distribution line to allow for boat storage facility construction.

Project consisted of the relocation of 0.2 miles of double circuit, three-phase overhead distribution line to allow for boat storage facility construction.

This project consisted of the relocation of 0.5 miles of single circuit overhead distribution line for a road widening project.

This project consisted of the relocation of sections of the street lighting system along US-31 through the City of Grand Haven to facilitate the widening and addition of left turn lanes by MDOT.

This project consisted of the relocation of 0.5 miles of double circuit overhead distribution line for a road widening project.

Project consisted of the conversion of double circuit 12.5kV line from Boyne City Substation for one-half mile to new accessible riser poles.

Project consisted of the reconstruction of four miles of three-phase overhead distribution line.

Project consisted of the reconstruction of 6.0 miles of V-phase and 6.5 miles of three-phase overhead distribution line.

Project consisted of the construction of 1.5 miles of double circuit three-phase overhead distribution line for voltage conversion to 12.5kV and shifting load to a new substation.

Project consisted of the underground conversion of one-half mile of primary & secondary electrical distribution system.